Stelpro Electric Baseboard Heaters London, Ontario
Stelpro Brava In Stock at MarsLED
London, Ontario • Electric Heating
Stelpro Electric Baseboard Heaters in London
Shop stocked Stelpro Brava electric baseboard heaters for London homes, rental properties, additional residential units, basement renovations, contractor projects and property-management applications. MarsLED carries 120 V and 240/208 V Brava models plus compatible built-in thermostat options.
Stelpro Brava London
Electric baseboard heating for London homes and projects.
Electric baseboard heating can be a practical option in London homes, rental units, additional residential units and renovation projects where the electrical and heating design calls for electric resistance heat. Stelpro Brava heaters provide multiple wattage and voltage configurations for project-specific selection.
Stelpro identifies Brava for bedrooms, dining rooms, living rooms and offices. Its rounded corners, one-piece rugged casing and installer-friendly design also make the platform useful for replacement work and ongoing property maintenance.
Why Brava?
Brava combines low-profile electric convection heat with the durability and clean appearance needed for residential and appropriate light-commercial environments.
- Rounded-corner design
- Rugged one-piece steel casing
- Quiet heating-element design
- Multiple wattage and voltage options
- Optional built-in thermostat control
London rental-heating context
London's Vital Services By-law specifically recognizes electrical baseboard heating systems.
London's current Vital Services By-law requires landlords to provide continuous heat to rented residential units from September 15 through June 15. The minimum is 20°C between 6:00 AM and 11:00 PM and 18°C at all other times.
Importantly for this product category, the by-law's definition of a heating system expressly includes an electrical baseboard heating system. Landlords must provide, maintain and repair the heating system so the required temperatures can be maintained. For London rental properties built around electric resistance heating, properly specified permanent baseboard heaters can therefore be directly relevant to replacement and maintenance work.
Stocked at MarsLED
Compare Stelpro Brava baseboard heaters.
Choose from the stocked MarsLED Brava range below. Heater selection should be based on the project's calculated heating load, voltage, circuit requirements, dimensions, clearances and applicable electrical requirements—not wattage or room size alone.
| Model | Power | Voltage | Length | Shop |
|---|---|---|---|---|
| B0501W | 500 W | 120 V | 27-7/8" | View B0501W |
| B0751W | 750 W | 120 V | 37-5/8" | View B0751W |
| B1001W | 1000 W | 120 V | 47-1/2" | View B1001W |
| B0502W | 500 / 375 W | 240 / 208 V | 27-7/8" | View B0502W |
| B0752W | 750 / 560 W | 240 / 208 V | 37-5/8" | View B0752W |
| B1002W | 1000 / 750 W | 240 / 208 V | 47-1/2" | View B1002W |
| B1502W | 1500 / 1125 W | 240 / 208 V | 66-1/4" | View B1502W |
| B2002W | 2000 / 1500 W | 240 / 208 V | 83-7/8" | View B2002W |
Electrical selection
120 V or 240/208 V? Match the heater to the project.
Voltage must match the electrical design and circuit serving the heater. When replacing an existing baseboard or planning a new installation, confirm voltage, wattage, circuit capacity and installation conditions before ordering.
B0501W • B0751W • B1001W
MarsLED stocks three 120 V Brava models from 500 W through 1000 W for projects designed around 120 V electric baseboard heating.
500 W through 2000 W
The stocked 240/208 V Brava range includes five models. Output is lower at 208 V, so both ratings are shown on the individual product pages.
London application guide
Where Brava fits into London projects.
Brava heaters can support a wide range of projects when electric resistance baseboard heat is appropriate for the building and the heater is correctly specified.
Replacement or new electric heating in bedrooms, living areas, offices, basements and additions.
Heating for permitted basement, converted-garage, detached or addition-based ARU projects where electric baseboard heat is part of the approved electrical and heating design.
Replacement and maintenance work in electrically heated rented residential units.
Stocked heater options for ongoing building maintenance, renovation and replacement programs.
Multiple wattage and voltage options for properly specified installation and retrofit work.
A familiar electric-heating platform for renovation, addition and residential construction projects.
Additional residential units in London
London permits up to four total dwelling units on qualifying residential properties.
London defines an Additional Residential Unit (ARU) as a self-contained dwelling unit located within the same building, or on the same lot, as an existing residential unit. The City identifies four main ARU types: interior or basement conversions, converted garages, detached ARUs and additions to an existing building.
Current City guidance permits up to four total dwelling units on a residential property where the zoning allows single-detached, semi-detached, duplex, triplex, converted or street-townhouse dwellings. Only two of the total units can be located in a detached building.
A building permit and a residential rental unit licence are required for all ARUs. London's current permit guidance also requires zoning review and project-specific building documentation, including HVAC design by a qualified designer where applicable. If electric baseboard heating forms part of the approved project, confirm heating load, voltage, wattage, circuit capacity, clearances and installation requirements before ordering.
London ARU considerations
- Confirm zoning compliance for the proposed ARU type
- Confirm the proposed configuration stays within the four-unit total
- Obtain the required building permit before construction
- Obtain the required residential rental unit licence
- Prepare required drawings, servicing details and HVAC documentation
- Match heater voltage and wattage to the approved electrical and heating design
Built-in temperature control
Complete the Brava installation with a Stelpro thermostat.
MarsLED stocks both built-in mechanical thermostat options. Compatibility and the correct control type should be confirmed for the specific heater and project before installation.
Single-Pole Built-In Thermostat
Mechanical 120–600 V built-in temperature control for compatible Stelpro baseboard heater installations.
View SIBT1WDouble-Pole Built-In Thermostat
Mechanical 120–600 V double-pole built-in thermostat for compatible Stelpro baseboard heater installations.
View SIBT2WLondon product questions
Stelpro baseboard heater FAQ — London
Where can I buy Stelpro Brava baseboard heaters for a London, Ontario project?
MarsLED stocks multiple Stelpro Brava 120 V and 240/208 V electric baseboard heaters for London homeowners, contractors, electricians, landlords and property-management customers.
What minimum temperatures does London's Vital Services By-law require in rental units?
London requires at least 20°C from 6:00 AM to 11:00 PM and at least 18°C at all other times from September 15 through June 15.
Does London's Vital Services By-law recognize electric baseboard heating?
Yes. The by-law's definition of a heating system expressly includes an electrical baseboard heating system.
Can Stelpro baseboard heaters be used in a London additional residential unit?
They can be considered where the permitted ARU's approved electrical and heating design calls for compatible electric baseboard heating. Heater selection should follow the project's zoning, building-permit, electrical and heating requirements.
How many dwelling units can be permitted on a London residential property?
London's current ARU guidance permits up to four total dwelling units on qualifying residential properties, subject to zoning and property-specific requirements.
What types of ARUs does London recognize?
London identifies four main types: interior or basement conversions, converted garages, detached ARUs and additions to existing buildings.
Does a London ARU require a building permit and rental licence?
Yes. London's current guidance states that a building permit and a residential rental unit licence are required for all ARUs.
Can I replace an old baseboard heater with a Brava model of the same wattage?
Not automatically. Confirm voltage, circuit requirements, calculated heating load, dimensions, clearances and installation requirements before choosing a replacement.
Should I buy a 120 V or 240 V baseboard heater?
The heater voltage must match the electrical design of the project. Confirm the existing circuit or project requirements before ordering.
Does MarsLED supply Stelpro heaters for contractor and property-management projects in London?
Yes. MarsLED's stocked Brava portfolio is available for residential, renovation, rental-property, contractor and property-management projects in London and Southwestern Ontario, subject to product availability.
Can a built-in thermostat be added to a Stelpro Brava heater?
Compatible Brava installations can use optional built-in thermostat controls. MarsLED stocks the Stelpro SIBT1W single-pole and SIBT2W double-pole thermostat options.
Shop Stelpro Brava heaters for London projects.
Compare stocked wattages, voltages and thermostat options from MarsLED.
