Stelpro Brava In Stock at MarsLED

Kingston, Ontario • Electric Heating

Stelpro Electric Baseboard Heaters in Kingston

Shop stocked Stelpro Brava electric baseboard heaters for Kingston homes, rental properties, additional residential units, basement renovations, contractor projects and property-management applications. MarsLED carries 120 V and 240/208 V Brava models plus compatible built-in thermostat options.

8 Stocked Brava Models120 V + 240/208 V
Rental & ARU ProjectsReplacement • Renovation • Maintenance
Kingston & Eastern OntarioAvailable Through MarsLED
Residential HeatingBedrooms, living areas & renovations
Rental PropertiesHeating maintenance & replacement
Additional Residential UnitsBasement • ARU • Detached Unit
Contractor ProjectsElectricians, GCs & retrofit work

Stelpro Brava Kingston

Electric baseboard heating for Kingston homes and projects.

Electric baseboard heating can be a practical option in Kingston homes, rental units, additional residential units and renovation projects where the electrical and heating design calls for electric resistance heat. Stelpro Brava heaters provide multiple wattage and voltage configurations for project-specific selection.

Stelpro identifies Brava for bedrooms, dining rooms, living rooms and offices. Its rounded corners, one-piece rugged casing and installer-friendly design also make the platform useful for replacement work and ongoing property maintenance.

Why Brava?

Brava combines low-profile electric convection heat with the durability and clean appearance needed for residential and appropriate light-commercial environments.

  • Rounded-corner design
  • Rugged one-piece steel casing
  • Quiet heating-element design
  • Multiple wattage and voltage options
  • Optional built-in thermostat control

Kingston property-standards context

Kingston requires dwelling heating systems capable of maintaining 21.1°C.

Kingston's current Property Standards By-law requires every dwelling unit to have a heating system capable of maintaining a minimum temperature of 21.1°C (70°F). Common areas and internal entranceways must have heating systems capable of maintaining at least 18°C.

For buildings rented or leased as living accommodation where the landlord normally provides the heat, the by-law requires adequate and suitable heat from September 15 through June 1, with a minimum air temperature of 21.1°C. Portable heating equipment cannot be used as the primary source of heat in a residential unit, and the heating system must be maintained in good working condition.

21.1°C Dwelling HeatMinimum heating-system capability required for Kingston dwelling units
18°C Common AreasMinimum heating capability required for common areas and internal entranceways

Stocked at MarsLED

Compare Stelpro Brava baseboard heaters.

Choose from the stocked MarsLED Brava range below. Heater selection should be based on the project's calculated heating load, voltage, circuit requirements, dimensions, clearances and applicable electrical requirements—not wattage or room size alone.

Model Power Voltage Length Shop
B0501W 500 W 120 V 27-7/8" View B0501W
B0751W 750 W 120 V 37-5/8" View B0751W
B1001W 1000 W 120 V 47-1/2" View B1001W
B0502W 500 / 375 W 240 / 208 V 27-7/8" View B0502W
B0752W 750 / 560 W 240 / 208 V 37-5/8" View B0752W
B1002W 1000 / 750 W 240 / 208 V 47-1/2" View B1002W
B1502W 1500 / 1125 W 240 / 208 V 66-1/4" View B1502W
B2002W 2000 / 1500 W 240 / 208 V 83-7/8" View B2002W

Electrical selection

120 V or 240/208 V? Match the heater to the project.

Voltage must match the electrical design and circuit serving the heater. When replacing an existing baseboard or planning a new installation, confirm voltage, wattage, circuit capacity and installation conditions before ordering.

120 V

B0501W • B0751W • B1001W

MarsLED stocks three 120 V Brava models from 500 W through 1000 W for projects designed around 120 V electric baseboard heating.

240 / 208 V

500 W through 2000 W

The stocked 240/208 V Brava range includes five models. Output is lower at 208 V, so both ratings are shown on the individual product pages.

Kingston application guide

Where Brava fits into Kingston projects.

Brava heaters can support a wide range of projects when electric resistance baseboard heat is appropriate for the building and the heater is correctly specified.

Home Renovations

Replacement or new electric heating in bedrooms, living areas, offices, basements and additions.

Additional Residential Units

Heating for permitted basement, interior, attached, detached or converted-garage ARU projects where electric baseboard heat is part of the approved electrical and heating design.

Rental Properties

Replacement and maintenance work in electrically heated rented residential units.

Property Management

Stocked heater options for ongoing building maintenance, renovation and replacement programs.

Electrical Contractors

Multiple wattage and voltage options for properly specified installation and retrofit work.

General Contractors

A familiar electric-heating platform for renovation, addition and residential construction projects.

Additional residential units in Kingston

Kingston supports interior, attached, detached and converted-garage ARU projects.

Kingston uses the term Additional Residential Unit (ARU) for an independent dwelling unit located within the same building or on the same property as a single-detached, semi-detached or townhouse dwelling. The City identifies four main ARU types: attached units, detached units, converted garages and interior or basement conversions.

Kingston allows ARUs on most properties, with important exceptions and restrictions. The City's current guidance identifies restricted areas including certain sewer-surcharging lands, lands with sewer-capacity limitations, Loughborough Lake lands and natural-hazard areas. Rural properties are also excluded from the City's general ARU eligibility guidance.

All new and existing ARUs must comply with the Ontario Building Code and require a building permit. Kingston's ARU permit guide identifies required project documentation such as plot plans, floor plans, elevations, cross-sections, spatial-separation calculations, mechanical design and energy-efficiency documentation.

Kingston also provides pre-reviewed detached ARU plans to speed design and permit review. These plans are pre-reviewed for Building Code compliance but still require a building-permit application and property-specific zoning review. If electric baseboard heating forms part of the approved design, confirm heating load, voltage, wattage, circuit capacity, clearances and installation requirements before ordering.

Kingston ARU considerations

  • Confirm zoning and property eligibility before design work
  • Check whether the property falls within a restricted servicing or hazard area
  • Confirm whether the project is interior, attached, detached or a converted garage
  • Obtain the required building permit before construction
  • Prepare mechanical-design and energy-efficiency documentation where required
  • Match heater voltage and wattage to the approved electrical and heating design

Built-in temperature control

Complete the Brava installation with a Stelpro thermostat.

MarsLED stocks both built-in mechanical thermostat options. Compatibility and the correct control type should be confirmed for the specific heater and project before installation.

SIBT1W

Single-Pole Built-In Thermostat

Mechanical 120–600 V built-in temperature control for compatible Stelpro baseboard heater installations.

View SIBT1W
SIBT2W

Double-Pole Built-In Thermostat

Mechanical 120–600 V double-pole built-in thermostat for compatible Stelpro baseboard heater installations.

View SIBT2W

Kingston product questions

Stelpro baseboard heater FAQ — Kingston

Where can I buy Stelpro Brava baseboard heaters for a Kingston project?

MarsLED stocks multiple Stelpro Brava 120 V and 240/208 V electric baseboard heaters for Kingston homeowners, contractors, electricians, landlords and property-management customers.

What minimum heating capability does Kingston require in dwelling units?

Kingston's current Property Standards By-law requires every dwelling unit to have a heating system capable of maintaining a minimum temperature of 21.1°C.

What temperature capability is required in Kingston common areas?

Common areas and internal entranceways must have heating systems capable of maintaining at least 18°C.

What temperature applies when a Kingston landlord normally provides the heat?

From September 15 through June 1, Kingston requires landlord-provided heat to maintain at least 21.1°C in rented or leased living accommodation where the landlord is normally responsible for heat.

Can portable heaters be the primary source of heat in a Kingston residential unit?

No. Kingston's Property Standards By-law states that portable heating equipment cannot serve as the primary source of heat in a residential unit.

What terminology does Kingston use for secondary residential units?

Kingston uses the term Additional Residential Unit, or ARU.

What types of ARUs does Kingston recognize?

Kingston identifies four main ARU types: attached units, detached units, converted garages and interior or basement conversions.

Are ARUs allowed on every Kingston property?

No. Kingston allows ARUs on most properties but identifies restrictions for certain servicing, sewer-surcharging, natural-hazard and other specified areas. Rural properties are excluded from the City's general ARU eligibility guidance.

Does a Kingston ARU require a building permit?

Yes. All new and existing additional residential units must comply with the Ontario Building Code and require a building permit.

Does Kingston offer pre-reviewed detached ARU plans?

Yes. Kingston provides pre-reviewed detached ARU plans to simplify design and permit review. Property-specific zoning review and a building-permit application are still required.

Can I replace an old baseboard heater with a Brava model of the same wattage?

Not automatically. Confirm voltage, circuit requirements, calculated heating load, dimensions, clearances and installation requirements before choosing a replacement.

Should I buy a 120 V or 240 V baseboard heater?

The heater voltage must match the electrical design of the project. Confirm the existing circuit or project requirements before ordering.

Does MarsLED supply Stelpro heaters for contractor and property-management projects in Kingston?

Yes. MarsLED's stocked Brava portfolio is available for residential, renovation, rental-property, contractor and property-management projects in Kingston and Eastern Ontario, subject to product availability.

Can a built-in thermostat be added to a Stelpro Brava heater?

Compatible Brava installations can use optional built-in thermostat controls. MarsLED stocks the Stelpro SIBT1W single-pole and SIBT2W double-pole thermostat options.

Shop Stelpro Brava heaters for Kingston projects.

Compare stocked wattages, voltages and thermostat options from MarsLED.

Shop Stelpro Baseboard Heaters