{"product_id":"hydel-ek400ro-200a-combination-isolated-neutral-meter-socket-4-jaw","title":"Hydel EK400RO 200A Combination Meter Socket with Isolated Neutral Capability | 4 Jaw | Ontario","description":"\u003cstyle\u003e\n  .mars-hydel-product {\n    font-family: Arial, Helvetica, sans-serif;\n    color: #1f2937;\n    line-height: 1.65;\n    max-width: 100%;\n  }\n  .mars-hydel-product * { box-sizing: border-box; }\n  .mars-hydel-product .mhp-wrap {\n    border: 1px solid #e5e7eb;\n    border-radius: 16px;\n    overflow: hidden;\n    background: #ffffff;\n    box-shadow: 0 8px 24px rgba(15, 23, 42, 0.06);\n    margin-bottom: 24px;\n  }\n  .mars-hydel-product .mhp-hero {\n    background: linear-gradient(135deg, #0f172a 0%, #1e293b 100%);\n    padding: 28px 22px;\n    color: #ffffff;\n  }\n  .mars-hydel-product .mhp-kicker {\n    display: inline-block;\n    background: #fbbf24;\n    color: #111827;\n    font-size: 12px;\n    font-weight: 700;\n    text-transform: uppercase;\n    letter-spacing: .5px;\n    padding: 7px 12px;\n    border-radius: 999px;\n    margin-bottom: 14px;\n  }\n  .mars-hydel-product .mhp-hero h2 {\n    color: #ffffff;\n    font-size: 30px;\n    line-height: 1.2;\n    margin: 0 0 10px;\n  }\n  .mars-hydel-product .mhp-hero p {\n    color: #e5e7eb;\n    margin: 0;\n    font-size: 15px;\n  }\n  .mars-hydel-product .mhp-badges {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 10px;\n    margin-top: 18px;\n  }\n  .mars-hydel-product .mhp-badge {\n    background: rgba(255,255,255,0.1);\n    border: 1px solid rgba(255,255,255,0.18);\n    color: #ffffff;\n    border-radius: 999px;\n    padding: 8px 12px;\n    font-size: 13px;\n    font-weight: 700;\n  }\n  .mars-hydel-product .mhp-section {\n    padding: 24px 22px;\n    border-top: 1px solid #e5e7eb;\n  }\n  .mars-hydel-product .mhp-section:first-child { border-top: 0; }\n  .mars-hydel-product .mhp-grid-2 {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0,1fr));\n    gap: 18px;\n  }\n  .mars-hydel-product .mhp-grid-3 {\n    display: grid;\n    grid-template-columns: repeat(3, minmax(0,1fr));\n    gap: 14px;\n  }\n  .mars-hydel-product .mhp-card {\n    border: 1px solid #e5e7eb;\n    border-radius: 14px;\n    background: #f8fafc;\n    padding: 16px;\n  }\n  .mars-hydel-product .mhp-card h3,\n  .mars-hydel-product .mhp-card h4 {\n    margin: 0 0 8px;\n    color: #111827;\n    line-height: 1.25;\n  }\n  .mars-hydel-product .mhp-card p {\n    margin: 0;\n    font-size: 14px;\n  }\n  .mars-hydel-product .mhp-alert {\n    background: linear-gradient(90deg, #fef3c7 0%, #fff7ed 100%);\n    border: 1px solid #f59e0b;\n    border-radius: 14px;\n    padding: 18px;\n  }\n  .mars-hydel-product .mhp-alert h3 {\n    margin: 0 0 8px;\n    color: #92400e;\n    font-size: 20px;\n  }\n  .mars-hydel-product .mhp-alert p {\n    margin: 0 0 10px;\n    color: #78350f;\n  }\n  .mars-hydel-product .mhp-alert ul {\n    margin: 0;\n    padding-left: 20px;\n    color: #78350f;\n  }\n  .mars-hydel-product .mhp-note {\n    font-size: 13px;\n    color: #6b7280;\n    margin-top: 10px;\n  }\n\n  .mars-hydel-product .mhp-tabs {\n    margin-top: 8px;\n  }\n  .mars-hydel-product .mhp-tabs input[type=\"radio\"] {\n    display: none;\n  }\n  .mars-hydel-product .mhp-tab-labels {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 8px;\n    margin-bottom: 14px;\n  }\n  .mars-hydel-product .mhp-tab-labels label {\n    display: inline-flex;\n    align-items: center;\n    gap: 8px;\n    cursor: pointer;\n    border: 1px solid #cbd5e1;\n    background: #f8fafc;\n    color: #111827;\n    padding: 12px 14px;\n    border-radius: 10px;\n    font-size: 14px;\n    font-weight: 700;\n    transition: all .2s ease;\n  }\n  .mars-hydel-product .mhp-tab-content {\n    display: none;\n    border: 1px solid #e5e7eb;\n    border-radius: 14px;\n    background: #ffffff;\n    padding: 18px;\n  }\n  #mhp-tab-1:checked ~ .mhp-tab-labels label[for=\"mhp-tab-1\"],\n  #mhp-tab-2:checked ~ .mhp-tab-labels label[for=\"mhp-tab-2\"],\n  #mhp-tab-3:checked ~ .mhp-tab-labels label[for=\"mhp-tab-3\"],\n  #mhp-tab-4:checked ~ .mhp-tab-labels label[for=\"mhp-tab-4\"],\n  #mhp-tab-5:checked ~ .mhp-tab-labels label[for=\"mhp-tab-5\"] {\n    background: #0f172a;\n    color: #ffffff;\n    border-color: #0f172a;\n  }\n  #mhp-tab-1:checked ~ .mhp-panels .mhp-panel-1,\n  #mhp-tab-2:checked ~ .mhp-panels .mhp-panel-2,\n  #mhp-tab-3:checked ~ .mhp-panels .mhp-panel-3,\n  #mhp-tab-4:checked ~ .mhp-panels .mhp-panel-4,\n  #mhp-tab-5:checked ~ .mhp-panels .mhp-panel-5 {\n    display: block;\n  }\n\n  .mars-hydel-product .mhp-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin-top: 10px;\n    font-size: 14px;\n  }\n  .mars-hydel-product .mhp-table th,\n  .mars-hydel-product .mhp-table td {\n    border: 1px solid #e5e7eb;\n    padding: 12px 10px;\n    text-align: left;\n    vertical-align: top;\n  }\n  .mars-hydel-product .mhp-table th {\n    background: #f1f5f9;\n    color: #111827;\n    font-weight: 700;\n  }\n\n  .mars-hydel-product .mhp-list,\n  .mars-hydel-product .mhp-links {\n    margin: 0;\n    padding-left: 20px;\n  }\n  .mars-hydel-product .mhp-list li,\n  .mars-hydel-product .mhp-links li {\n    margin-bottom: 8px;\n  }\n\n  .mars-hydel-product .mhp-downloads {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0,1fr));\n    gap: 12px;\n    margin-top: 12px;\n  }\n  .mars-hydel-product .mhp-download {\n    display: flex;\n    align-items: center;\n    gap: 12px;\n    text-decoration: none;\n    color: #111827 !important;\n    border: 1px solid #e5e7eb;\n    border-radius: 14px;\n    background: #f8fafc;\n    padding: 14px;\n    font-weight: 700;\n  }\n  .mars-hydel-product .mhp-download:hover {\n    border-color: #94a3b8;\n    background: #f1f5f9;\n  }\n  .mars-hydel-product .mhp-icon {\n    width: 42px;\n    height: 42px;\n    min-width: 42px;\n    border-radius: 10px;\n    display: inline-flex;\n    align-items: center;\n    justify-content: center;\n    background: #fff7ed;\n    border: 1px solid #fdba74;\n    font-size: 20px;\n  }\n\n  .mars-hydel-product .mhp-cta {\n    border: 1px solid #cbd5e1;\n    border-radius: 14px;\n    padding: 18px;\n    background: #f8fafc;\n  }\n  .mars-hydel-product .mhp-cta h3 {\n    margin: 0 0 8px;\n    color: #111827;\n  }\n  .mars-hydel-product .mhp-btn-row {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 10px;\n    margin-top: 14px;\n  }\n  .mars-hydel-product .mhp-btn {\n    display: inline-block;\n    text-decoration: none;\n    border-radius: 10px;\n    padding: 11px 16px;\n    font-weight: 700;\n    border: 1px solid #d97706;\n    background: #f59e0b;\n    color: #111827 !important;\n  }\n  .mars-hydel-product .mhp-btn-secondary {\n    background: #ffffff;\n    border-color: #cbd5e1;\n  }\n\n  .mars-hydel-product .mhp-faq {\n    border: 1px solid #e5e7eb;\n    border-radius: 14px;\n    overflow: hidden;\n    margin-top: 12px;\n  }\n  .mars-hydel-product .mhp-faq details {\n    border-top: 1px solid #e5e7eb;\n    background: #ffffff;\n  }\n  .mars-hydel-product .mhp-faq details:first-child {\n    border-top: none;\n  }\n  .mars-hydel-product .mhp-faq summary {\n    list-style: none;\n    cursor: pointer;\n    padding: 16px;\n    background: #f8fafc;\n    font-weight: 700;\n    color: #111827;\n  }\n  .mars-hydel-product .mhp-faq summary::-webkit-details-marker {\n    display: none;\n  }\n  .mars-hydel-product .mhp-faq .mhp-faq-body {\n    padding: 16px;\n    color: #374151;\n  }\n\n  .mars-hydel-product a {\n    color: #1d4ed8;\n  }\n\n  @media (max-width: 768px) {\n    .mars-hydel-product .mhp-grid-2,\n    .mars-hydel-product .mhp-grid-3,\n    .mars-hydel-product .mhp-downloads {\n      grid-template-columns: 1fr;\n    }\n    .mars-hydel-product .mhp-hero h2 {\n      font-size: 24px;\n    }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"mars-hydel-product\"\u003e\n  \u003cdiv class=\"mhp-wrap\"\u003e\n    \u003cdiv class=\"mhp-hero\"\u003e\n      \u003cdiv class=\"mhp-kicker\"\u003eOntario Meter Base • Hydel EK400RO\u003c\/div\u003e\n      \u003ch2\u003eHydel EK400RO 200A Combination Meter Socket with Isolated Neutral Capability, 4 Jaw, Oversize Enclosure\u003c\/h2\u003e\n      \u003cp\u003e\n        The \u003cstrong\u003eHydel EK400RO\u003c\/strong\u003e is a \u003cstrong\u003e200 amp, 600 volt, 4-jaw combination overhead\/underground meter socket\u003c\/strong\u003e designed for utility-facing residential and light commercial service installations. This model features an \u003cstrong\u003eoversize enclosure\u003c\/strong\u003e, \u003cstrong\u003ebarrel-type line connectors angled at 45°\u003c\/strong\u003e, and a \u003cstrong\u003eNo. 6–250 MCM CU\/AL conductor range\u003c\/strong\u003e. For Ontario applications where isolated neutral configuration is preferred, the EK series supports the \u003cstrong\u003eHydel INK200 insulated neutral accessory\u003c\/strong\u003e.\n      \u003c\/p\u003e\n      \u003cdiv class=\"mhp-badges\"\u003e\n        \u003cspan class=\"mhp-badge\"\u003e200A\u003c\/span\u003e\n        \u003cspan class=\"mhp-badge\"\u003e600V\u003c\/span\u003e\n        \u003cspan class=\"mhp-badge\"\u003eOH \/ UG Combination\u003c\/span\u003e\n        \u003cspan class=\"mhp-badge\"\u003e4 Jaw\u003c\/span\u003e\n        \u003cspan class=\"mhp-badge\"\u003eOversize Enclosure\u003c\/span\u003e\n        \u003cspan class=\"mhp-badge\"\u003eINK200 Capable\u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"mhp-section\"\u003e\n      \u003cdiv class=\"mhp-alert\"\u003e\n        \u003ch3\u003e⚠️ Isolated Neutral Preference in Ontario\u003c\/h3\u003e\n        \u003cp\u003e\n          On Ontario jobs, utilities often prefer the neutral to be isolated from the meter-mounting device on applicable models. The Hydel EK series lists the \u003cstrong\u003eINK200 insulated neutral\u003c\/strong\u003e as a field-adaptable accessory, which makes the EK400RO relevant where isolated neutral configuration may be required by the service design, utility guide, or inspector.\n        \u003c\/p\u003e\n        \u003cul\u003e\n          \u003cli\u003eHydro One gives preference to isolating the neutral from the meter-mounting device on applicable models.\u003c\/li\u003e\n          \u003cli\u003eThe EK series includes \u003cstrong\u003eINK200 insulated neutral\u003c\/strong\u003e as a field-adaptable accessory.\u003c\/li\u003e\n          \u003cli\u003eFinal approval depends on the exact SKU, installed configuration, utility requirements, and inspection method.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"mhp-note\"\u003e\n        \u003cdiv style=\"margin-top:14px;padding:14px 16px;border:1px solid #e5e7eb;border-radius:12px;background:#f8fafc;\"\u003e\n  \u003cstrong style=\"display:block;margin-bottom:6px;color:#111827;\"\u003eWhat is INK200?\u003c\/strong\u003e\n  \u003cp style=\"margin:0;color:#374151;line-height:1.6;\"\u003e\n    For Ontario applications where isolated neutral configuration is preferred, the Hydel EK series supports the\n    \u003cstrong\u003eINK200 insulated neutral accessory\u003c\/strong\u003e. Hydro One guidance gives preference to isolating the neutral\n    from the meter-mounting device on applicable models, while ESA guidance requires the neutral assembly and bonding\n    method to match the grounding approach used on the installation. Final configuration should always be confirmed\n    against the current utility guide and inspection requirements.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n        Always confirm the exact meter-base configuration, grounding method, and utility acceptance before installation and energization.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"mhp-section\"\u003e\n      \u003cdiv class=\"mhp-grid-3\"\u003e\n        \u003cdiv class=\"mhp-card\"\u003e\n          \u003ch3\u003e🔌 Combination OH \/ UG Design\u003c\/h3\u003e\n          \u003cp\u003eDesigned for \u003cstrong\u003ecombination overhead and underground\u003c\/strong\u003e service entry applications, making it suitable for a wider range of field conditions than a single-entry-only base.\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"mhp-card\"\u003e\n          \u003ch3\u003e🧰 Hydel INK200 Capability\u003c\/h3\u003e\n          \u003cp\u003eThe EK series supports the \u003cstrong\u003eINK200 insulated neutral\u003c\/strong\u003e accessory, helping contractors configure the meter base appropriately where isolated neutral treatment is preferred or required.\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"mhp-card\"\u003e\n          \u003ch3\u003e📐 Oversize Enclosure\u003c\/h3\u003e\n          \u003cp\u003eBuilt with an \u003cstrong\u003eoversize enclosure\u003c\/strong\u003e and barrel-type connectors angled at 45°, making it a practical choice for service-entry installations requiring extra working space.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"mhp-section\"\u003e\n      \u003cdiv class=\"mhp-tabs\"\u003e\n        \u003cinput type=\"radio\" name=\"mhp-tabs\" id=\"mhp-tab-1\" checked\u003e\n        \u003cinput type=\"radio\" name=\"mhp-tabs\" id=\"mhp-tab-2\"\u003e\n        \u003cinput type=\"radio\" name=\"mhp-tabs\" id=\"mhp-tab-3\"\u003e\n        \u003cinput type=\"radio\" name=\"mhp-tabs\" id=\"mhp-tab-4\"\u003e\n        \u003cinput type=\"radio\" name=\"mhp-tabs\" id=\"mhp-tab-5\"\u003e\n\n        \u003cdiv class=\"mhp-tab-labels\"\u003e\n          \u003clabel for=\"mhp-tab-1\"\u003e📋 Overview\u003c\/label\u003e\n          \u003clabel for=\"mhp-tab-2\"\u003e📐 Specifications\u003c\/label\u003e\n          \u003clabel for=\"mhp-tab-3\"\u003e🆚 EK400RO vs EK400ROBC\u003c\/label\u003e\n          \u003clabel for=\"mhp-tab-4\"\u003e📄 Downloads\u003c\/label\u003e\n          \u003clabel for=\"mhp-tab-5\"\u003e❓ FAQs\u003c\/label\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"mhp-panels\"\u003e\n          \u003cdiv class=\"mhp-tab-content mhp-panel-1\"\u003e\n            \u003ch3\u003eHydel EK400RO Meter Socket Overview\u003c\/h3\u003e\n            \u003cp\u003e\n              The \u003cstrong\u003eHydel EK400RO\u003c\/strong\u003e is a \u003cstrong\u003e200A combination overhead\/underground meter socket\u003c\/strong\u003e for service entrance applications where a \u003cstrong\u003e4-jaw, 600V, single-position meter base\u003c\/strong\u003e with an \u003cstrong\u003eoversize enclosure\u003c\/strong\u003e is required. It is especially relevant for Ontario contractors looking for a Hydel combination meter base that can support isolated-neutral configuration through the \u003cstrong\u003eINK200 insulated neutral accessory\u003c\/strong\u003e.\n            \u003c\/p\u003e\n            \u003cbr\u003e\n            \u003cp\u003e\n              Common buying phrases for this unit include \u003cstrong\u003eHydel EK400RO\u003c\/strong\u003e, \u003cstrong\u003e200A combination meter socket\u003c\/strong\u003e, \u003cstrong\u003eoverhead underground meter base\u003c\/strong\u003e, \u003cstrong\u003eHydel 4 jaw meter socket\u003c\/strong\u003e, \u003cstrong\u003eOntario 200A meter base\u003c\/strong\u003e, and \u003cstrong\u003eisolated neutral capable meter base\u003c\/strong\u003e.\n            \u003c\/p\u003e\n            \u003cbr\u003e\n            \u003cul class=\"mhp-list\"\u003e\n              \u003cli\u003eIdeal for projects requiring combination overhead \/ underground entry\u003c\/li\u003e\n              \u003cli\u003eUseful where an oversize enclosure is preferred\u003c\/li\u003e\n              \u003cli\u003eSupports isolated-neutral-capable configuration through Hydel INK200\u003c\/li\u003e\n              \u003cli\u003eSuitable for electricians, builders, and electrical wholesalers in Ontario\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"mhp-tab-content mhp-panel-2\"\u003e\n            \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n            \u003ctable class=\"mhp-table\"\u003e\n              \u003ctr\u003e\n                \u003cth\u003eSpecification\u003c\/th\u003e\n                \u003cth\u003eDetails\u003c\/th\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eManufacturer\u003c\/td\u003e\n                \u003ctd\u003eHydel\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eModel\u003c\/td\u003e\n                \u003ctd\u003eEK400RO\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eType\u003c\/td\u003e\n                \u003ctd\u003eCombination overhead \/ underground meter socket\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eAmperage Rating\u003c\/td\u003e\n                \u003ctd\u003e200A\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eVoltage Rating\u003c\/td\u003e\n                \u003ctd\u003e600V\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eJaw Configuration\u003c\/td\u003e\n                \u003ctd\u003e4 Jaw\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eConnection Type\u003c\/td\u003e\n                \u003ctd\u003eBarrel-type connectors angled at 45°\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eConductor Range\u003c\/td\u003e\n                \u003ctd\u003eNo. 6 – 250 MCM CU\/AL\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eEnclosure\u003c\/td\u003e\n                \u003ctd\u003eCSA enclosure 3R\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eDimensions\u003c\/td\u003e\n                \u003ctd\u003e18\" H x 12\" W x 4-3\/4\" D\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eWeight\u003c\/td\u003e\n                \u003ctd\u003e15 lbs\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eAccessory Option\u003c\/td\u003e\n                \u003ctd\u003eINK200 insulated neutral (field adaptable)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eApplication\u003c\/td\u003e\n                \u003ctd\u003eCombination OH \/ UG service entrance\u003c\/td\u003e\n              \u003c\/tr\u003e\n            \u003c\/table\u003e\n\n            \u003cdiv class=\"mhp-grid-2\" style=\"margin-top:18px;\"\u003e\n              \u003cdiv class=\"mhp-card\"\u003e\n                \u003ch4\u003eTypical Applications\u003c\/h4\u003e\n                \u003cul class=\"mhp-list\"\u003e\n                  \u003cli\u003eResidential service entrances\u003c\/li\u003e\n                  \u003cli\u003eCombination OH \/ UG service configurations\u003c\/li\u003e\n                  \u003cli\u003eUtility-facing meter installations\u003c\/li\u003e\n                  \u003cli\u003eOntario contractor supply and replacement jobs\u003c\/li\u003e\n                \u003c\/ul\u003e\n              \u003c\/div\u003e\n              \u003cdiv class=\"mhp-card\"\u003e\n                \u003ch4\u003eWhy Contractors Choose This Model\u003c\/h4\u003e\n                \u003cul class=\"mhp-list\"\u003e\n                  \u003cli\u003eHydel brand familiarity in Ontario\u003c\/li\u003e\n                  \u003cli\u003eCombination service entry flexibility\u003c\/li\u003e\n                  \u003cli\u003eOversize enclosure format\u003c\/li\u003e\n                  \u003cli\u003eSupports insulated-neutral configuration with INK200\u003c\/li\u003e\n                \u003c\/ul\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"mhp-tab-content mhp-panel-3\"\u003e\n            \u003ch3\u003eHydel EK400RO vs Hydel EK400ROBC\u003c\/h3\u003e\n            \u003cp\u003e\n              These two Hydel EK-family models are closely related, but they are not identical. The main practical difference is that the \u003cstrong\u003eEK400ROBC\u003c\/strong\u003e is specifically listed by Hydro One as an acceptable-example 200A overhead\/underground model, while the Hydel catalogue shows the \u003cstrong\u003eEK400ROBC\u003c\/strong\u003e with a \u003cstrong\u003e3\" knockout in the bottom\u003c\/strong\u003e and deeper enclosure dimensions than the standard EK400RO.\n            \u003c\/p\u003e\n\n            \u003ctable class=\"mhp-table\"\u003e\n              \u003ctr\u003e\n                \u003cth\u003eFeature\u003c\/th\u003e\n                \u003cth\u003eEK400RO\u003c\/th\u003e\n                \u003cth\u003eEK400ROBC\u003c\/th\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eAmperage\u003c\/td\u003e\n                \u003ctd\u003e200A\u003c\/td\u003e\n                \u003ctd\u003e200A\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eVoltage\u003c\/td\u003e\n                \u003ctd\u003e600V\u003c\/td\u003e\n                \u003ctd\u003e600V\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eType\u003c\/td\u003e\n                \u003ctd\u003eCombination OH \/ UG\u003c\/td\u003e\n                \u003ctd\u003eCombination OH \/ UG\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eJaw Configuration\u003c\/td\u003e\n                \u003ctd\u003e4 Jaw\u003c\/td\u003e\n                \u003ctd\u003e4 Jaw\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eDepth\u003c\/td\u003e\n                \u003ctd\u003e4-3\/4\"\u003c\/td\u003e\n                \u003ctd\u003e5-1\/8\"\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eBottom KO Note\u003c\/td\u003e\n                \u003ctd\u003eStandard EK400RO format\u003c\/td\u003e\n                \u003ctd\u003ec\/w 3\" KO in bottom\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eHydro One Acceptable-Example Listing\u003c\/td\u003e\n                \u003ctd\u003eVerify exact project suitability\u003c\/td\u003e\n                \u003ctd\u003eListed by Hydro One\u003c\/td\u003e\n              \u003c\/tr\u003e\n            \u003c\/table\u003e\n\n            \u003cdiv class=\"mhp-note\"\u003e\n              If your Ontario project needs exact Hydro One list alignment, verify whether EK400ROBC is the correct SKU before finalizing the product title and field application.\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"mhp-tab-content mhp-panel-4\"\u003e\n            \u003ch3\u003eDownloads \u0026amp; Resources\u003c\/h3\u003e\n            \u003cp\u003e\n              Use the resources below to review Hydel product-family references, utility acceptance guidance, and related meter-base options.\n            \u003c\/p\u003e\n\n            \u003cdiv class=\"mhp-downloads\"\u003e\n              \u003ca class=\"mhp-download\" href=\"https:\/\/www.hydelinc.com\/wp-content\/uploads\/2023\/04\/Hydel_Fullline_Cat_2018.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n                \u003cspan class=\"mhp-icon\"\u003e📘\u003c\/span\u003e\n                \u003cspan\u003eHydel Full Line Catalogue\u003c\/span\u003e\n              \u003c\/a\u003e\n\n              \u003ca class=\"mhp-download\" href=\"https:\/\/www.hydroone.com\/businessservices_\/Standards\/CSA-Approved_Meter-Mounting_Devices.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n                \u003cspan class=\"mhp-icon\"\u003e📄\u003c\/span\u003e\n                \u003cspan\u003eHydro One Meter-Mounting Device Guide\u003c\/span\u003e\n              \u003c\/a\u003e\n\n              \u003ca class=\"mhp-download\" href=\"https:\/\/shopmarsled.com\/collections\/electric-meter-bases\" target=\"_blank\" rel=\"noopener\"\u003e\n                \u003cspan class=\"mhp-icon\"\u003e⚡\u003c\/span\u003e\n                \u003cspan\u003eBrowse All Electric Meter Bases\u003c\/span\u003e\n              \u003c\/a\u003e\n\n              \u003ca class=\"mhp-download\" href=\"https:\/\/shopmarsled.com\/pages\/shipping-policy\" target=\"_blank\" rel=\"noopener\"\u003e\n                \u003cspan class=\"mhp-icon\"\u003e🚚\u003c\/span\u003e\n                \u003cspan\u003eMarsLED Shipping Policy\u003c\/span\u003e\n              \u003c\/a\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv class=\"mhp-grid-2\" style=\"margin-top:18px;\"\u003e\n              \u003cdiv class=\"mhp-card\"\u003e\n                \u003ch4\u003eWhat the Hydel catalogue confirms\u003c\/h4\u003e\n                \u003cul class=\"mhp-list\"\u003e\n                  \u003cli\u003e200A, 600V, 4-jaw EK400RO configuration\u003c\/li\u003e\n                  \u003cli\u003eOversize enclosure dimensions and weight\u003c\/li\u003e\n                  \u003cli\u003eBarrel-type connectors angled at 45°\u003c\/li\u003e\n                  \u003cli\u003eINK200 insulated neutral as a field-adaptable accessory\u003c\/li\u003e\n                \u003c\/ul\u003e\n              \u003c\/div\u003e\n              \u003cdiv class=\"mhp-card\"\u003e\n                \u003ch4\u003eWhat Hydro One confirms\u003c\/h4\u003e\n                \u003cul class=\"mhp-list\"\u003e\n                  \u003cli\u003ePreference for isolating the neutral on applicable models\u003c\/li\u003e\n                  \u003cli\u003eEK400ROBC listed as an acceptable-example 200A OH\/UG model\u003c\/li\u003e\n                  \u003cli\u003eUnlisted models may still be installed if they meet Hydro One requirements\u003c\/li\u003e\n                  \u003cli\u003eFinal acceptance depends on exact model and installation details\u003c\/li\u003e\n                \u003c\/ul\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n\n          \u003cdiv class=\"mhp-tab-content mhp-panel-5\"\u003e\n            \u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n            \u003cdiv class=\"mhp-faq\"\u003e\n              \u003cdetails open\u003e\n                \u003csummary\u003eWhat is the Hydel EK400RO used for?\u003c\/summary\u003e\n                \u003cdiv class=\"mhp-faq-body\"\u003e\n                  The Hydel EK400RO is a 200A, 600V, 4-jaw combination overhead\/underground meter socket used for utility-facing service entrance applications.\n                \u003c\/div\u003e\n              \u003c\/details\u003e\n\n              \u003cdetails\u003e\n                \u003csummary\u003eDoes the EK400RO support isolated neutral?\u003c\/summary\u003e\n                \u003cdiv class=\"mhp-faq-body\"\u003e\n                  The EK series supports \u003cstrong\u003eHydel INK200 insulated neutral\u003c\/strong\u003e as a field-adaptable accessory. That means the EK400RO can be positioned as having \u003cstrong\u003eisolated neutral capability\u003c\/strong\u003e, but the final installed configuration should be confirmed for the exact job.\n                \u003c\/div\u003e\n              \u003c\/details\u003e\n\n              \u003cdetails\u003e\n                \u003csummary\u003eIs the EK400RO an overhead or underground meter base?\u003c\/summary\u003e\n                \u003cdiv class=\"mhp-faq-body\"\u003e\n                  It is a \u003cstrong\u003ecombination OH \/ UG\u003c\/strong\u003e design, meaning it is used for both overhead and underground entry configurations.\n                \u003c\/div\u003e\n              \u003c\/details\u003e\n\n              \u003cdetails\u003e\n                \u003csummary\u003eWhat conductor range does the EK400RO support?\u003c\/summary\u003e\n                \u003cdiv class=\"mhp-faq-body\"\u003e\n                  Hydel lists the conductor range as \u003cstrong\u003eNo. 6 to 250 MCM copper or aluminum\u003c\/strong\u003e.\n                \u003c\/div\u003e\n              \u003c\/details\u003e\n\n              \u003cdetails\u003e\n                \u003csummary\u003eIs EK400RO approved for Ontario?\u003c\/summary\u003e\n                \u003cdiv class=\"mhp-faq-body\"\u003e\n                  Ontario acceptance should always be verified against the exact SKU, the current utility requirements, and the authority having jurisdiction. Hydro One specifically lists \u003cstrong\u003eEK400ROBC\u003c\/strong\u003e as an acceptable-example 200A OH\/UG model, while unlisted models may still be used if they comply with Hydro One’s requirements.\n                \u003c\/div\u003e\n              \u003c\/details\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"mhp-section\"\u003e\n      \u003cdiv class=\"mhp-cta\"\u003e\n        \u003ch3\u003eContractor Pricing for Meter Bases \u0026amp; Service Entrance Products\u003c\/h3\u003e\n        \u003cp\u003e\n          Working on a residential, utility-facing, or electrical service project in Ontario? Contact MarsLED for contractor pricing, sourcing support, and meter-base supply across Ontario and Canada.\n        \u003c\/p\u003e\n        \u003cdiv class=\"mhp-btn-row\"\u003e\n          \u003ca class=\"mhp-btn\" href=\"tel:+19058789997%20or%20+15198936666\"\u003eCall 905-878-9997 or 519-893-6666\u003c\/a\u003e\n          \u003ca class=\"mhp-btn mhp-btn-secondary\" href=\"mailto:email.sales@marsled.com\"\u003eEmail.sales@marsled.com\u003c\/a\u003e\n          \u003ca class=\"mhp-btn mhp-btn-secondary\" href=\"https:\/\/shopmarsled.com\/collections\/electric-meter-bases\"\u003eShop Meter Bases\u003c\/a\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003cdiv style=\"margin-top:14px;padding:14px 16px;border:1px solid #e5e7eb;border-radius:12px;background:#f8fafc;\"\u003e\n\u003cstrong style=\"display:block;margin-bottom:6px;color:#111827;\"\u003eLooking for an isolated neutral meter base?\u003c\/strong\u003e\n\u003cp style=\"margin:0;color:#374151;line-height:1.6;\"\u003e\nFor Ontario underground service installations requiring isolated neutral configurations, see the \n\u003ca href=\"\/products\/hydel-msc400tw-200a-underground-meter-socket-isolated-neutral\"\u003e\u003cstrong\u003eHydel MSC400TW meter socket\u003c\/strong\u003e\u003c\/a\u003e\nor the\n\u003ca href=\"\/products\/hydel-msc400tw3-200a-underground-meter-socket-isolated-neutral\"\u003e\u003cstrong\u003eHydel MSC400TW3\u003c\/strong\u003e\u003c\/a\u003e.\n\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"mhp-section\"\u003e\n      \u003ch3\u003eExplore More Electrical Service Products\u003c\/h3\u003e\n      \u003cul class=\"mhp-links\"\u003e\n        \u003cli\u003e\u003ca href=\"https:\/\/shopmarsled.com\/collections\/electric-meter-bases\"\u003eBrowse all electric meter bases\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca href=\"https:\/\/shopmarsled.com\/products\/hydel-msc400tw-200a-underground-meter-socket-isolated-neutral\"\u003eView Hydel MSC400TW isolated-neutral meter socket\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca href=\"https:\/\/shopmarsled.com\/products\/hydel-msc400tw3-200a-underground-meter-socket-isolated-neutral\"\u003eView Hydel MSC400TW3 isolated-neutral meter socket\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n      \u003cp class=\"mhp-note\"\u003e\n        MarsLED supplies meter bases and service entrance products to electricians and contractors across Toronto, Mississauga, Brampton, Vaughan, Hamilton, Milton, Kitchener-Waterloo, Cambridge, London, Ottawa, Barrie, Kingston and across Ontario.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydel","offers":[{"title":"Default Title","offer_id":46508734087357,"sku":"EK400RO","price":89.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0288\/7273\/6802\/files\/EK400RO-MAIN.png?v=1773695648","url":"https:\/\/shopmarsled.com\/products\/hydel-ek400ro-200a-combination-isolated-neutral-meter-socket-4-jaw","provider":"MARS LED","version":"1.0","type":"link"}